A refrigerant leak gets worse, not better
A heat pump low on refrigerant will keep running, but the compressor has to work harder to move heat with less of it. That extra strain wears the compressor down faster than the leak itself ever would.
Takes about a minute. No obligation.
Heat pumps here run heat from October through May and switch to cooling in June. That changeover in late May and the first cold stretch in September are when a weak part finally gives out. A capacitor that was marginal all spring can fail the day the system switches over to cooling. A reversing valve that stuck once in the fall may stick again when it's asked to work in October. If your heat pump is acting up right at the start of a season, that timing is a clue worth passing along to whoever comes to look at it.

NOAA nClimDiv, 1991–2020 normals
Winona winters average 11°F overnight, cold enough that a heat pump leans on its backup heat strip most nights.
A system that cycles on backup heat a lot wears the same parts an AC would in any climate, so look for the usual suspects first.



Winona County sees its share of weather, 63 damaging wind events and 83 hail events in the past decade. None of that points at your heat pump specifically. Hail can dent a cabinet or bend fins on the outdoor unit, and a bad storm can knock out power long enough to matter, but those are the same risks a heat pump faces anywhere storms like this roll through. If your power was out for a while, check the breaker and the disconnect near the outdoor unit before anything else. Otherwise the fault is probably inside the system itself, not something the weather did to it.
Minnesota electricity ran 15.45 cents per kilowatthour in 2024, and your heat pump leans hard on backup heat strip all winter. A system that's cycling wrong or stuck on backup heat is burning power every hour it runs that way. Get it looked at before another cold stretch runs up the bill.
Find a contractorA heat pump usually tells you something is wrong before it quits outright. Warm air blowing when it should be cooling, or cool air when it should be heating, often means the reversing valve isn't shifting the way it should. Ice building up on the outdoor coil and not clearing during the defrost cycle points at the defrost board or its sensor. A unit that short cycles, turning on and off every few minutes instead of running a full cycle, is often a bad capacitor or a control board losing its nerve. Listen for it too. A hard clunk at startup, a hum with no fan movement, or a grinding sound from the outdoor unit are all signs of a part that's close to done rather than one that just needs time. The system that limps along making noise or short cycling for weeks is wearing itself out faster than the one that fails clean and all at once.
A heat pump low on refrigerant will keep running, but the compressor has to work harder to move heat with less of it. That extra strain wears the compressor down faster than the leak itself ever would.
If the valve won't shift all the way, the system can end up pulling from both sides at once. Running it in that state stresses the compressor directly, so a problem that started in the valve can end up a compressor problem instead.
Most heat pump failures trace back to a handful of parts that do the most work. The contactor clicks in every time the compressor starts, and over thousands of cycles the contacts pit and burn until they stick or stop closing. The run capacitor sits there storing a charge to kick the compressor and fan motor into motion, and it weakens with age and heat until the motor it serves starts struggling to start. The defrost board and its sensor decide when to melt frost off the outdoor coil, and when the sensor drifts or the board fails the unit either frosts over solid or runs defrost cycles it doesn't need. Fan motor bearings wear out from spinning for years in the weather. None of these wait for a dramatic moment. They just wear a little more each season until one day they don't work at all.
A diagnostic starts with the thermostat, confirming what the system is actually set to do versus what it's doing. From there a technician checks line voltage and the condensing unit outside, reading pressures and temperatures to see whether the system has the right refrigerant charge and whether the compressor is pulling the current it should. They'll test the reversing valve directly, forcing a switch between heating and cooling to see if it actually shifts or just hums and stays put. The contactor and capacitor get checked by hand since both fail in ways you can see and measure before they fail completely. Airflow gets a look too, because a coil choked with ice or a blower not moving enough air can mimic a refrigerant problem that isn't really there. By the end they can usually point to the one part causing the trouble rather than guessing at the whole system.